| Availability: | |
|---|---|
| Quantity: | |
Meitong Nickel Coated Copper Wire is a copper conductor with a protective nickel coating, designed for use in high-temperature electrical wiring, industrial equipment, and specialized cable manufacturing.
The copper core provides electrical conductivity, while the nickel coating helps protect the conductor surface against oxidation during exposure to elevated temperatures. This combination makes nickel plated copper wire a suitable material for applications where bare copper may experience accelerated surface oxidation.
Meitong offers nickel coated copper wire in nominal diameters from 0.05 mm to 3.26 mm, with published nickel coating thicknesses ranging from 0.3 μm to 5.0 μm. Both soft and hard wire conditions are listed in the product specifications.
The product is marketed for heat-resistant applications up to 450°C. The actual permissible operating temperature depends on the conductor specification, exposure duration, surrounding environment, and insulation or cable assembly design.
For specialized electrical and industrial applications, wire diameter, coating thickness, mechanical properties, and packaging requirements can be discussed according to project needs.
Nickel coating provides a protective surface that helps reduce oxidation of copper under elevated-temperature conditions.
This makes nickel coated copper conductors useful in the manufacture of heat-resistant wiring and electrical assemblies.
For applications approaching 450°C, the permissible exposure temperature and duration should be confirmed using the relevant material data and completed cable specifications.
Copper can oxidize when exposed to heat and air. A suitable nickel coating helps limit direct exposure of the copper surface to the surrounding environment.
The effectiveness of the coating depends on its thickness, continuity, surface condition, and operating conditions.
The copper core provides the primary electrical conduction path.
Nickel plated copper wire can be selected for electrical connections where both conductivity and surface protection are required. The actual conductor resistance should be evaluated according to the wire diameter, material condition, and applicable technical specification.
Meitong's published nominal diameter range of 0.05–3.26 mm covers fine and larger conductor sizes for different manufacturing requirements.
Diameter selection should consider electrical resistance, mechanical strength, processing methods, and the design of the finished component.
The published specifications include soft and hard wire conditions, allowing buyers to evaluate the required balance between forming characteristics and mechanical strength.
The appropriate condition depends on the intended processing and application.
The published nickel coating thickness range is 0.3–5.0 μm.
Different coating requirements may be evaluated according to the required surface protection, processing method, and service environment.
The following specifications are based on Meitong's published nickel coated copper wire data.
Parameter | Specification |
|---|---|
Product Name | Nickel Coated Copper Wire |
Alternative Name | Nickel Plated Copper Wire |
Base Material | Copper |
Surface Coating | Nickel |
Nominal Wire Diameter | 0.05–3.26 mm |
Nickel Coating Thickness | 0.3–5.0 μm |
Tensile Strength – Soft Condition | ≥196 MPa |
Tensile Strength – Hard Condition | ≥350 MPa |
Diameter Tolerance | According to the table below |
Referenced Standards | GB/T 11019 and ASTM B355-95, as stated on the existing product page |
Surface Appearance | Free from visible scratches, oil stains, exposed copper, and oxidation |
Published Packaging | 8-inch, 9-inch, and Type 300 plastic reels |
Customization | Available upon technical confirmation |
Nominal Diameter (mm) | Published Diameter Tolerance |
|---|---|
0.05 ≤ d ≤ 0.10 | ±0.002 mm |
0.10 < d ≤ 0.23 | ±0.003 mm |
0.23 < d ≤ 0.50 | ±0.004 mm |
0.50 < d ≤ 3.26 | To be confirmed from the approved specification |
The following properties should be confirmed according to the selected wire diameter and material condition:
Electrical resistivity
Elongation
Nickel coating thickness and uniformity
Coating adhesion
Surface quality
Applicable inspection and acceptance requirements
The published product information references GB/T 11019-2021 for electrical resistivity and elongation. Buyers should request the applicable values for their selected specification.
Technical Note: Nickel coated copper wire is a conductor material. Its suitability for a particular voltage, temperature, or electrical installation must be determined by the design and ratings of the completed insulated wire or cable assembly.
Nickel coated copper wire consists of a copper conductor with a nickel coating applied to its surface.
The copper core provides electrical conductivity and the mechanical characteristics required for subsequent wire processing.
Depending on the selected diameter and material condition, the wire may be used as an individual conductor or as a component in further conductor manufacturing.
The nickel coating acts as a protective surface layer, helping improve resistance to oxidation during exposure to elevated temperatures.
Coating thickness and surface quality are important considerations for applications involving heat, conductor processing, and electrical termination.
Nickel coated copper wire may be incorporated into stranded conductor constructions for specialized cable applications.
The suitability and availability of a particular strand configuration should be confirmed according to the required conductor size, flexibility, and manufacturing specifications.
Nickel coated copper wire is used as a conductor material in electrical and industrial applications where elevated temperatures or oxidation exposure must be considered.
Nickel plated copper conductors can be used in the manufacture of heat-resistant wires and cables.
The finished cable may incorporate appropriate high-temperature insulation materials selected according to the required operating temperature and electrical conditions.
Nickel coated copper wire may be considered for electrical connections associated with industrial ovens, furnaces, heating appliances, and temperature-control equipment.
It serves as an electrical conductor rather than a resistance heating element. The final wiring design must account for conductor temperature, current, insulation, and installation conditions.
Nickel plated copper conductors may be used in selected automotive wiring assemblies, including applications located near high-temperature components.
Material selection should consider temperature exposure, vibration, electrical requirements, and the specifications of the completed wiring harness.
Nickel coated copper conductors are used in certain specialized electrical cable constructions where high-temperature performance and surface protection are required.
For aerospace or other safety-critical applications, material specifications, traceability, testing, and applicable qualification requirements must be verified before use.
The material may be considered for selected sensor wiring and electrical connections exposed to elevated temperatures.
Wire diameter, electrical resistance, termination compatibility, and environmental conditions should be evaluated according to the intended equipment.
Nickel coated copper wire quality should be evaluated through conductor dimensions, mechanical properties, electrical performance, and coating characteristics.
Meitong's existing product information references:
GB/T 11019
ASTM B355-95
The applicable standard edition and conformity of the ordered specification should be confirmed through the approved technical documentation.
Wire Diameter Inspection
Verify nominal diameter and dimensional tolerance against the ordered specification.
Nickel Coating Inspection
Evaluate coating thickness, surface condition, and other specified coating requirements.
Mechanical Property Testing
Review tensile strength and elongation according to the selected wire condition.
Electrical Property Testing
Confirm electrical resistance or resistivity using the applicable test method and acceptance criteria.
Surface Appearance Inspection
Check for visible scratches, contamination, oxidation, or exposed copper that may affect product acceptance.
Buyers requiring specific certificates, inspection records, or material documentation should confirm availability before ordering.
Different electrical and industrial applications may require different conductor dimensions, surface specifications, and packaging formats.
Meitong's published product information includes the following options.
Customization Item | Available Information |
|---|---|
Wire Diameter | Published range: 0.05–3.26 mm |
Nickel Coating Thickness | Published range: 0.3–5.0 μm |
Material Condition | Soft and hard conditions |
Wire Configuration | Special strand constructions subject to confirmation |
Mechanical Properties | Requirements to be evaluated against manufacturing capability |
Packaging | 8-inch, 9-inch, and Type 300 plastic reels |
Special Requirements | Subject to technical review |
For applications requiring insulation, shielding, or completed cable assemblies, please confirm the available product scope and technical requirements with Meitong before placing an order.
To help identify a suitable specification, please provide:
Required wire diameter and tolerance
Nickel coating thickness
Soft or hard material condition
Required electrical or mechanical properties
Intended application and temperature conditions
Estimated order quantity
Packaging and documentation requirements
Nickel coated copper wire is a copper conductor with a nickel layer applied to its surface.
The copper core provides electrical conductivity, while the nickel coating helps protect the conductor surface against oxidation, particularly in elevated-temperature applications.
The product is marketed for heat-resistant applications up to 450°C. However, this value should not automatically be treated as the continuous operating temperature of every wire size or finished cable assembly.
Permissible operating conditions depend on the conductor specification, exposure duration, insulation system, and applicable test requirements.
Both materials use copper conductors with metallic surface coatings.
Tin plating is commonly used for surface protection and termination-related requirements in electrical applications. Nickel plating is often selected where higher-temperature oxidation resistance is an important consideration.
The appropriate material depends on operating temperature, electrical requirements, termination method, and the finished product design.
Meitong's published nickel coated copper wire specifications cover nominal diameters from 0.05 mm to 3.26 mm and nickel coating thicknesses from 0.3 μm to 5.0 μm.
Availability of individual diameter and coating combinations should be confirmed before ordering.
Nickel coated copper wire can be used as a component in certain stranded conductor constructions.
The required strand count, individual wire diameter, flexibility, and electrical performance should be specified according to the intended cable design.
Nickel surfaces generally require different termination considerations from bare or tin plated copper.
Solderability depends on surface condition, flux, solder alloy, process temperature, and any applicable surface treatment. Buyers should validate the intended joining method before production.
Please provide the required wire diameter, nickel coating thickness, material condition, quantity, intended application, and any special inspection or packaging requirements.
These details help clarify the product specification and quotation requirements.
Depending on the required operating temperature, conductor structure, and surface properties, buyers may also consider the following materials:
Tin Plated Copper Wire / Stranded Wire
Silver Plated Copper Wire / Stranded Wire
Nickel Plated Copper Strip
Nickel Plated Copper-clad Steel
Nickel Plated Stainless Steel Wire
Different conductor materials and coatings offer different electrical, mechanical, and environmental characteristics. The final selection should be based on the intended application.
Looking for nickel coated copper wire for high-temperature cable manufacturing or specialized electrical applications?
Meitong supplies nickel plated copper wire in a range of published diameters and coating specifications for industrial conductor applications.
Contact our team with your required wire diameter, nickel coating thickness, material condition, order quantity, and technical requirements.
Send Your Inquiry to Meitong for Product Specifications and Quotation Details.
Nickel Coated Copper Wire | ||||
Standard: GB11019 / ASTMB355—95 or customized | ||||
Nominal Diameter(mm) | ||||
0.05≤d≤0.1 | 0.1<d≤0.23 | 0.23<d≤0.5 | 0.5<d≤3.26 | |
Tolerance(mm) | ±0.002 | ±0.003 | ±0.004 | ±d% |
Electrical Resistivity | GB/T11019-2021 form5 | |||
Elongation(%) | GB/T11019-2021 form4 | |||
Tensile Strength(Mpa) | Soft:≥196 Hard:≥350 | |||
Coating Lay thickness(um) | 0.3-5.0um | |||
Exterior | No scratches, oil stains,copper exposure,oxidation.etc | |||
packing | 8inch9inchtype300-plastic reel | |||
Note | Can be customized | |||