H1Z2Z2-K Solar Cable is designed for electrical connections in photovoltaic (PV) power generation systems, including solar module interconnections, DC string wiring, and connections to compatible DC combiner boxes and inverters.
The cable features a flexible Class 5 tinned copper conductor with cross-linked, halogen-free insulation and sheathing materials. This construction is intended to provide electrical insulation, installation flexibility, and resistance to environmental conditions commonly encountered in outdoor solar installations.
Meitong offers H1Z2Z2-K photovoltaic cables for solar power applications. Available specifications and technical requirements can be discussed according to the intended installation and project needs.
Parameter | Specification |
|---|---|
Product Name | H1Z2Z2-K Solar Cable |
Cable Type | Photovoltaic DC Cable |
Rated Voltage | AC 0.6/1kV; DC 1.5kV |
Conductor Material | Flexible Tinned Copper |
Conductor Class | Class 5 |
Insulation | Cross-linked Halogen-free Compound |
Outer Sheath | Cross-linked Halogen-free Compound |
Referenced Standards | EN 50618 / IEC 62930 (applicability to be verified) |
Conductor Cross-section | Tinned copper: 35mm² |
Main Applications | Photovoltaic DC Wiring and Solar Power Systems |
The construction of H1Z2Z2-K photovoltaic cable is an important consideration for electrical performance, installation flexibility, and long-term operation.
The cable uses a Class 5 flexible tinned copper conductor. The stranded construction supports cable routing and installation, while the tin coating helps protect the copper surface against oxidation.
The insulation layer provides electrical separation between the conductor and the surrounding environment. Its cross-linked material structure is intended for the thermal and electrical requirements of photovoltaic cable applications.
The outer sheath provides an additional protective layer against environmental exposure and mechanical contact during installation and operation.
Its suitability for UV exposure, moisture, temperature variations, and specific installation environments should be assessed according to the applicable product standard and verified test data.
Class 5 stranded tinned copper provides flexibility for routing cables through photovoltaic installations, including module connections and cable management systems.
The H1Z2Z2-K cable is intended for photovoltaic DC circuits with the specified rated voltage. Actual system compatibility must be evaluated according to the electrical design and applicable installation requirements.
The cable incorporates cross-linked insulation and sheathing materials intended to support electrical insulation and environmental performance.
The use of halogen-free insulation and sheathing materials is relevant to projects where cable material composition and fire-performance requirements must be considered.
The cable can be considered for various PV DC connections, subject to cable sizing, installation conditions, applicable standards, and project specifications.
H1Z2Z2-K solar cables are selected according to conductor cross-section, rated voltage, electrical resistance, installation conditions, and required current-carrying capacity.
The technical specification section should include the manufacturer's verified data for each available cable size.
Technical Parameter | Information to Display |
|---|---|
Nominal Cross-section | Available conductor sizes in mm² |
Conductor Construction | Class 5 tinned copper |
Insulation Thickness | Nominal thickness by cable size |
Overall Diameter | Approximate cable diameter |
Conductor Resistance | Maximum DC resistance at 20°C |
Insulation Resistance | Verified value and test conditions |
Current Carrying Capacity | Rated current under defined installation conditions |
Minimum Bending Radius | Verified value according to cable specification |
Operating Temperature | Approved operating temperature range |
Short-circuit Temperature | Verified maximum conductor temperature and duration |
Important: Current-carrying capacity depends on installation method, ambient temperature, cable grouping, and other operating conditions. Values from different cable types or test conditions should not be used interchangeably.
H1Z2Z2-K solar cable is primarily used for DC electrical connections in photovoltaic power generation systems.
The cable can be used to connect compatible photovoltaic modules and associated DC wiring components, subject to the system design and connection requirements.
It can be used for DC connections within photovoltaic strings and between solar strings and compatible DC collection equipment.
H1Z2Z2-K cables may be used to connect photovoltaic strings to DC combiner boxes where the selected cable size, voltage rating, and installation method meet the project requirements.
The cable may be used on the DC side of photovoltaic inverters when the electrical ratings and installation conditions are compatible.
H1Z2Z2-K cables can be considered for rooftop and ground-mounted photovoltaic installations, including larger solar power generation projects.
The installation method, mechanical protection, environmental exposure, and cable routing requirements should be evaluated for each project.
Selecting the correct photovoltaic cable requires more than choosing a conductor cross-section.
Verify that the cable's rated voltage is suitable for the maximum DC voltage of the photovoltaic system.
Select the conductor cross-section according to the expected operating current, permissible voltage drop, cable length, and applicable electrical design requirements.
Consider whether the cable will be installed outdoors, inside conduits, on cable trays, or in other protected locations.
Direct burial and continuous movement applications require separate confirmation of product suitability.
Check the expected ambient temperature, UV exposure, moisture conditions, and other environmental factors that may affect cable selection.
Confirm the standards, test reports, and certification requirements for the destination market and photovoltaic project.
Where the cable is used with photovoltaic connectors, verify compatibility with the connector manufacturer's specified conductor sizes, cable diameters, and termination requirements.
H1Z2Z2-K solar cable is used for DC electrical connections in photovoltaic power generation systems, including solar module wiring, string connections, and compatible DC collection equipment.
H1Z2Z2-K and PV1-F are photovoltaic cable designations associated with different technical specifications and standard frameworks. They should not be considered interchangeable without checking their rated voltages, material construction, testing requirements, and project specifications.
The selection depends on operating current, cable length, voltage drop, ambient temperature, installation method, and applicable electrical requirements. Neither size should be selected solely on the basis of its nominal cross-section.
H1Z2Z2-K cable is intended for photovoltaic applications that commonly involve outdoor exposure. The specific cable's environmental suitability should be verified against its approved technical data and applicable standards.
Direct burial suitability should not be assumed from the H1Z2Z2-K designation alone. The cable manufacturer's instructions, relevant standards, and installation protection requirements must be checked before underground installation.
Buyers should provide the required conductor cross-section, cable quantity or length, project voltage, applicable standards, destination market, and any specific packaging or installation requirements.
Looking for H1Z2Z2-K solar cable for your photovoltaic project?
Meitong supplies wire and cable products for industrial and electrical applications. For H1Z2Z2-K photovoltaic cable inquiries, please share your required conductor size, quantity, applicable standards, and intended application.
Contact our team to discuss product specifications, technical documentation, and quotation requirements.
Technical Specifications of H1Z2Z2-K 1.5kV DC Solar Cable Models
Model | Rated voltage | Conductor cross section | Name | Standard number |
H1Z2Z2-K | AC:0.6/1kV; DC:1.5kV | 2.5-240mm² | Copper core cross-linked polyolefin insulated solar photovoltaic cable | prEN 50618: 2014 |
PV1-F | AC:0.6/1kV DC:1.8kV | 2.5-35mm² | 2 Pfg 1169/08.2007 |
Section(mm²) | (Tinned copper) Type of conductor | Insulation thickness | Approximate outer diameter | 90°C Min Insulation Resistance MQ.km | 20°C Max Conductor Resistance (Q2/km) | ||
PV1-F | H1Z272-K | PV1-F | H1Z272-K | ||||
2.5 | 5 | 0.6 | 0.7 | 5.5 | 5.9 | 0.69 | 8.21 |
4 | 5 | 0.6 | 0.7 | 6.2 | 6.6 | 0.58 | 5.09 |
6 | 5 | 0.6 | 0.7 | 6.8 | 7.2 | 0.5 | 3.39 |
10 | 5 | 0.7 | 0.8 | 7.9 | 8.3 | 0.42 | 1.95 |
16 | 5 | 0.7 | 0.8 | 9.2 | 9.6 | 0.34 | 1.24 |
25 | 5 | 0.7 | 1.0 | 11.2 | 11.7 | 0.34 | 0.795 |
35 | 5 | 0.7 | 1.0 | 12.2 | 13.6 | 0.29 | 0.565 |
Nominal section(mm²) | Installation method(A) | ||
Exposure to the air | Laying on the surface | Surface connection | |
1.5 | 30 | 29 | 24 |
2.5 | 41 | 39 | 33 |
4 | 55 | 52 | 44 |
6 | 70 | 67 | 57 |
Nominal section(mm²) | Installation method(A) | ||
Exposure to the air | Laying on the surface | Surface connection | |
10 | 98 | 93 | 79 |
16 | 132 | 125 | 107 |
25 | 176 | 167 | 142 |
35 | 218 | 207 | 176 |
Ambient temperature (℃) | Below 60 | 70 | 80 | 90 | 100 | 110 |
Conversion factor | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |
Model | Name | Application condition | |
PV/LH-F | Aluminum alloy core solar photovoltaic cable | AA:0.6/1KV | |
AAPV1-F | |||
PV1500V-DC | |||
Section mm² | Insulation thickness | Approxima outside diameter | Reference weight(kg/km) | Maximum resistance at 20 ℃ (Ω/km) |
1.5 | 0.7 | 4.5 | 27 | 19.9 |
2.5 | 0.7 | 5.0 | 34 | 11.9 |
4 | 0.7 | 6.0 | 42 | 7.45 |
6 | 0.7 | 6.2 | 52 | 4.96 |
10 | 0.8 | 8.3 | 87 | 2.98 |
16 | 0.8 | 9.4 | 112 | 1.86 |
25 | 1.0 | 11.7 | 172 | 1.19 |
35 | 1.0 | 13.6 | 220 | 0.827 |
50 | 1.2 | 16.0 | 310 | 0.579 |
70 | 1.2 | 18.1 | 413 | 0.413 |
95 | 1.4 | 20.4 | 542 | 0.331 |
120 | 1.4 | 22.3 | 644 | 0.248 |
150 | 1.6 | 25.5 | 730 | 0.199 |
185 | 1.6 | 28.0 | 895 | 0.156 |
240 | 1.8 | 31.7 | 1015 | 0.124 |
Nominal section | Installation method | ||
Single core cable exposed to the air | Single core cable laid on the surface | single core cable which surface connected | |
1.5 | 24 | 23 | 19 |
2.5 | 32 | 32 | 26 |
4 | 43 | 41 | 35 |
6 | 55 | 53 | 45 |
10 | 77 | 73 | 62 |
16 | 104 | 99 | 85 |
25 | 139 | 132 | 112 |
35 | 172 | 164 | 139 |
50 | 225 | 214 | 182 |
70 | 261 | 248 | 211 |
95 | 336 | 319 | 272 |
120 | 407 | 387 | 330 |
150 | 462 | 439 | 374 |
185 | 514 | 488 | 416 |
240 | 616 | 585 | 499 |
Ambient temperature(℃) | Below 60 | 70.0 | 80 | 90 | 100 | 110 | |
Conversion factor | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 | |