| Availability: | |
|---|---|
| Quantity: | |
Meitong Silver Plated Copper Stranded Wire is a flexible electrical conductor made from multiple silver-coated copper wires. It combines the electrical conductivity of copper with the surface properties of silver, making it suitable for selected electronic, industrial cable, and signal transmission applications.
The stranded construction provides flexibility for conductor processing and cable assembly. The silver coating helps protect the copper surface against oxidation and can offer useful surface conductivity and solderability characteristics for suitable electrical applications.
Meitong's published product specifications include 7–100 individual strands, single-wire diameters from 0.05 mm to 0.5 mm, and silver coating thicknesses from 0.3 μm to 2.0 μm.
Different strand constructions, lay directions, and packaging options are available according to the published product information. Buyers can select the appropriate conductor configuration based on electrical resistance, mechanical requirements, manufacturing processes, and intended applications.
Each conductor strand consists of a copper core with a silver-plated surface.
Copper provides the primary electrical conduction path, while the silver layer contributes to the surface characteristics of the conductor.
This construction can be useful in electrical assemblies requiring conductive surfaces, oxidation resistance, or specific termination properties.
The conductor consists of multiple individual wires rather than a single solid wire.
The stranded structure provides flexibility and can facilitate conductor routing, termination, and further cable manufacturing.
Actual bending performance depends on the strand diameter, conductor construction, material condition, and finished cable design.
Silver plated copper stranded wire provides an electrical conduction path for power and signal applications.
The conductor's overall electrical resistance depends on copper material properties, individual strand dimensions, strand count, lay length, and coating characteristics.
For high-frequency applications, silver plating may influence conductor surface losses because current distribution changes with frequency. Actual performance must be evaluated according to the operating frequency and conductor design.
Silver coating provides a metallic surface layer over the copper conductor.
It can help reduce direct oxidation of the underlying copper, although silver itself may tarnish under certain environmental conditions.
Coating thickness, continuity, and surface condition should be considered when selecting the conductor.
Silver plated copper can provide a solderable surface for suitable electrical assembly processes.
Solderability depends on surface cleanliness, storage conditions, flux, solder alloy, and process temperature.
Meitong's published product specifications include 7–100 strands, S or Z lay directions, and silver coating thicknesses from 0.3 μm to 2.0 μm.
These options allow buyers to evaluate conductor constructions for different electrical and manufacturing requirements.
Parameter | Specification |
|---|---|
Product Name | Silver Plated Copper Stranded Wire |
Alternative Name | Silver Coated Copper Stranded Conductor |
Base Material | Copper |
Surface Coating | Silver |
Individual Wire Diameter | 0.05–0.50 mm |
Number of Strands | 7–100 |
Lay Direction | S or Z |
Silver Coating Thickness | 0.3–2.0 μm |
Tensile Strength | ≥196 MPa (published value) |
Elongation | Varies by individual wire diameter |
Electrical Resistivity | Varies by individual wire diameter |
Surface Requirements | No visible scratches, oil contamination, exposed copper, or oxidation abnormalities |
Packaging | DIN200, DIN300, DIN400, DIN500 and specified steel reels |
Special Specifications | Subject to technical confirmation |
Individual Wire Diameter (mm) | Diameter Tolerance (mm) | Electrical Resistivity (Ω·mm²/m) | Elongation |
|---|---|---|---|
0.05 ≤ d ≤ 0.09 | ±0.003 | ≤0.01851 | ≥6% |
0.09 < d ≤ 0.25 | ±0.004 | ≤0.01802 | ≥12% |
0.25 < d ≤ 0.50 | ±0.005 | ≤0.01770 | ≥15% |
The above values are based on the published product specifications. The applicable material condition, test method, and acceptance criteria should be confirmed before ordering.
The required conductor construction should be specified using the following information:
Number of individual wires
Nominal diameter of each wire
Total conductor cross-sectional area
Overall stranded conductor diameter
Lay direction and lay length
Electrical resistance
Required mechanical properties
For example, a conductor designation such as 7 × 0.10 mm indicates seven individual wires, each with a nominal diameter of 0.10 mm.
This is an illustration of strand designation, not a confirmed stock specification.
The electrical resistance of the completed stranded conductor is affected by the total copper cross-sectional area, strand construction, and processing conditions.
Mechanical performance is influenced by individual strand diameter, material condition, stranding method, and the design of the finished assembly.
Buyers should request the applicable stranded conductor data when selecting materials for a specific cable or electronic component.
Silver plated copper stranded wire consists of multiple silver-coated copper wires assembled into a stranded conductor.
The copper core provides electrical conductivity and contributes to the mechanical characteristics of the individual wire.
The selected copper material and processing condition affect electrical resistance, tensile strength, and elongation.
A silver layer is applied to the surface of the individual copper wires.
The published coating thickness range is 0.3–2.0 μm.
The required coating thickness should be selected according to the electrical application, processing requirements, and applicable material specifications.
Multiple silver plated copper wires are assembled into a flexible conductor.
The published strand count range is 7–100, with S or Z lay direction options.
Strand count and individual wire diameter determine the nominal metal cross-sectional area and contribute to the overall conductor dimensions.
The finished wire should have a clean and consistent surface without visible defects that may affect processing or product acceptance.
The applicable surface quality requirements should be agreed upon according to the purchasing specification.
Silver plated copper stranded conductors may be used in selected signal transmission cables and high-frequency electrical assemblies.
The silver surface can be relevant to conductor loss characteristics at higher frequencies, while the stranded construction supports cable manufacturing and routing requirements.
Actual signal performance depends on the complete cable design, including conductor geometry, insulation, shielding, and operating frequency.
Silver plated copper stranded wire can be considered for flexible electrical conductors used in robotic equipment, automation systems, and control cable assemblies.
For moving cable applications, conductor flexibility, bending radius, strand construction, and fatigue performance must be evaluated together.
The number of bending cycles supported by the finished cable should be confirmed through application-specific testing.
The conductor may be used in selected automotive electronic wiring and cable assemblies.
Potential applications include signal connections, control circuits, and specialized electronic components where suitable electrical and mechanical properties are required.
Automotive use should be verified against the relevant temperature, vibration, electrical, and qualification requirements.
Fine stranded copper conductors can be used in selected precision electronic assemblies where conductor dimensions, flexibility, and electrical resistance are important.
The final conductor configuration should be selected according to the electrical design and manufacturing process.
Silver plated copper stranded wire may be incorporated into industrial instrumentation and specialized electrical cable constructions.
Material selection should account for environmental conditions, electrical requirements, cable insulation, and installation methods.
The quality of silver plated copper stranded wire should be evaluated through conductor dimensions, electrical properties, mechanical performance, and plating characteristics.
The applicable material and conductor standards should be confirmed according to the ordered specification and destination market.
The product's published information references ASTM B961-13 and other technical requirements. Buyers should verify whether the referenced standard applies to the specific silver plated copper wire and stranding construction being ordered.
Certifications for a finished insulated cable should not automatically be treated as certifications for an individual bare stranded conductor.
Individual Wire Diameter
Verify nominal diameter and dimensional tolerance.
Silver Coating Thickness
Check the coating thickness according to the agreed specification.
Electrical Resistivity
Measure the electrical resistivity of individual wires or resistance of the finished conductor using the applicable test method.
Mechanical Properties
Evaluate tensile strength and elongation against the required material condition.
Stranding Construction
Inspect strand count, lay direction, conductor dimensions, and visible construction defects.
Surface Appearance
Check for scratches, contamination, exposed copper, and other unacceptable surface conditions.
Buyers requiring specific inspection records, material certificates, or test reports should confirm their availability before ordering.
Meitong's published silver plated copper stranded wire specifications cover multiple conductor configurations and coating requirements.
Item | Published Specification or Option |
|---|---|
Individual Wire Diameter | 0.05–0.50 mm |
Strand Count | 7–100 |
Silver Coating Thickness | 0.3–2.0 μm |
Lay Direction | S or Z |
Electrical Properties | According to selected conductor specification |
Mechanical Properties | According to selected material condition |
Packaging | DIN200, DIN300, DIN400, DIN500 and specified steel reels |
Special Constructions | Subject to technical review |
Buyers may provide technical drawings or specifications for review.
Important requirements include:
Individual wire diameter and tolerance
Strand count and conductor construction
Overall conductor diameter
Silver coating thickness
Lay direction and lay length
Electrical resistance requirements
Mechanical properties
Packaging requirements
Estimated order quantity
For projects requiring insulated or shielded cable assemblies, please confirm the available manufacturing scope and technical requirements separately.
Silver plated copper stranded wire is a conductor made from multiple copper wires with silver-coated surfaces.
It combines the electrical properties of copper, the surface characteristics of silver, and the flexibility of a stranded construction.
Both products use copper conductors with metallic surface coatings.
Silver plating is often selected for specific electrical surface characteristics and certain high-frequency applications.
Tin plating is commonly used for surface protection and electrical termination requirements.
The appropriate coating depends on operating temperature, frequency, termination method, environmental conditions, and cost requirements.
Silver plated copper wire has a copper core with a silver coating on its surface.
Silver copper alloy wire contains silver and copper as alloy constituents within the material.
Their mechanical, electrical, and processing properties depend on the specific material composition and manufacturing condition.
The published product specifications include 7–100 individual strands and individual wire diameters from 0.05 mm to 0.50 mm.
Specific strand combinations and dimensional requirements should be confirmed before ordering.
Silver plated copper conductors can be considered for certain high-frequency applications because conductor surface properties become more significant as operating frequency increases.
However, the electrical performance of the finished cable depends on the complete conductor and cable design.
Silver plating alone does not guarantee a particular signal loss or transmission performance.
Stranded conductors provide flexibility, but suitability for continuous movement depends on strand construction, bending radius, mechanical loading, and the complete cable assembly.
Dynamic bending performance should be confirmed through appropriate testing.
Please provide the individual wire diameter, strand count, silver coating thickness, lay direction, required electrical or mechanical properties, order quantity, and intended application.
A technical drawing or conductor specification can help clarify special requirements.
Buyers evaluating silver plated copper stranded wire may also consider other conductor materials according to their electrical, mechanical, and surface requirements.
Tin Plated Copper Stranded Wire
Ultra Fine Silver Coated Copper Stranded Wire
Ultra Fine Silver Plated Copper Wire
Nickel Coated Copper Wire
Silver Plated Copper-clad Steel Wire
Each conductor type offers different characteristics. The final selection should be based on the intended application and required technical specifications.
Looking for silver plated copper stranded wire for electronic equipment, flexible cable manufacturing, or specialized conductor applications?
Meitong provides silver plated copper stranded wire with published strand counts of 7–100, individual wire diameters from 0.05 mm to 0.50 mm, and silver coating thicknesses from 0.3 μm to 2.0 μm.
Please share your required conductor construction, wire diameter, silver coating thickness, electrical specifications, and order quantity.
Contact Meitong to discuss technical requirements, available specifications, and quotation details.
Understanding the precise capabilities of your conductive materials is essential for system design. Our stranded conductors are engineered to deliver exceptional electrical and thermal ratings, supporting up to 300V rated voltage and enduring extreme temperatures up to 250℃. This ensures outstanding dielectric strength and operational safety in high-frequency, high-voltage, and harsh thermal environments. Furthermore, every batch undergoes rigorous quality control and testing protocols. This includes comprehensive flame retardant testing such as the VW-1 standard, dielectric withstand evaluations, and micron-level dimensional tolerance inspections. These strict testing measures guarantee that the mechanical and electrical performance of every single wire remains highly consistent, facilitating seamless integration into your final assemblies.
Silver Plated Copper Wire - Stranded | |||
Project | Diameter(mm) | ||
0.05≤d≤0.09 | 0.09<d≤0.25 | 0.25<d≤0.5 | |
tolerance(mm) | ±0.003 | ±0.004 | ±0.005 |
electrical resistivity | ≤0.01851 | ≤0.01802 | ≤0.0177 |
Elongation(%) | ≥6 | ≥12 | ≥15 |
number wire | 7-100 | ||
lay direction | S OR Z | ||
Resistance(mm) | 2.0—100mm | ||
Tensile Strength(Mpa) | ≥196 | ||
plating(um) | 0.3-2.0um | ||
appearance | No scratches, oil, copper exposure, oxidation and other abnormalities | ||
Package | DIN200DIN300DIN400 rubber disc, 400 type steel disc, DIN500 steel disc, etc | ||